.IX Title "VIRT-P2V 1"
-.TH VIRT-P2V 1 "2008-02-04" "virt-p2v-0.9.1" "Virtualization Support"
+.TH VIRT-P2V 1 "2008-02-07" "virt-p2v-0.9.3" "Virtualization Support"
.SH "NAME"
virt\-p2v \- P2V (physical to virtual machine) migration tool
.SH "SUMMARY"
In this mode, the live \s-1CD\s0 attempts to reuse the network configuration
from the physical machine's root filesystem. You should probably try
this method even though occasionally it does not work.
+.IP "Ask for fixed \s-1IP\s0 address and gateway" 4
+.IX Item "Ask for fixed IP address and gateway"
+In this mode the live \s-1CD\s0 will ask you for a fixed \s-1IP\s0 address and
+gateway address, and will configure your chosen interface with these.
.IP "Configure from the shell" 4
.IX Item "Configure from the shell"
In this mode you will be dropped into a command shell and you will
.Sp
where \f(CW\*(C`AA.BB.CC.DD\*(C'\fR is the \s-1IP\s0 address and \f(CW\*(C`GG.HH.II.JJ\*(C'\fR is the
gateway.
+.IP "\s-1QEMU\s0 user network" 4
+.IX Item "QEMU user network"
+This option configures the network for use inside a \s-1QEMU\s0 user network
+(<http://fabrice.bellard.free.fr/qemu/qemu\-doc.html#SEC30>). It
+should only be used by developers.
.RE
.RS 4
.RE
addresses are not tested for uniqueness so there is a very small
chance that they could coincide, which would leave a guest unable to
access the virtual network.
+.IP "Compression" 4
+.IX Item "Compression"
+Choose whether to enable or disable compression on disk images as they
+are copied across the network.
+.Sp
+If enabled, the \f(CW\*(C`\-C\*(C'\fR option is passed to \fIssh\fR\|(1). On fast networks
+this can sometimes be slower.
+.Sp
+\&\s-1NB:\s0 The disk image is still stored uncompressed on the remote host
+however this option is set.
.IP "Verify and proceed" 4
.IX Item "Verify and proceed"
In this step you are asked to verify the settings above. If any are
.ie n .IP """network""" 4
.el .IP "\f(CWnetwork\fR" 4
.IX Item "network"
-Set this to the choice for network setup. Use either \f(CW\*(C`Some Auto\*(C'\fR or
-\&\f(CW\*(C`Some Shell\*(C'\fR for auto-configuration or shell (manual) configuration
-respectively.
+Set this to the choice for network setup. Use one of:
+.RS 4
+.ie n .IP """Some Auto""" 4
+.el .IP "\f(CWSome Auto\fR" 4
+.IX Item "Some Auto"
+for auto-configuration
+.ie n .IP """Some Static""" 4
+.el .IP "\f(CWSome Static\fR" 4
+.IX Item "Some Static"
+to specify the interface, address, netmask and gateway statically
+.ie n .IP """Some Shell""" 4
+.el .IP "\f(CWSome Shell\fR" 4
+.IX Item "Some Shell"
+to launch a shell
+.ie n .IP """Some QEMUUserNet""" 4
+.el .IP "\f(CWSome QEMUUserNet\fR" 4
+.IX Item "Some QEMUUserNet"
+to use a \s-1QEMU\s0 user network (developers only)
+.RE
+.RS 4
+.RE
+.ie n .IP """static_network_config""" 4
+.el .IP "\f(CWstatic_network_config\fR" 4
+.IX Item "static_network_config"
+This setting only applies if \f(CW\*(C`network\*(C'\fR is set to \f(CW\*(C`Some Static\*(C'\fR,
+in which case you should set this to the static network settings,
+a tuple of (interface, address, netmask, gateway, nameserver):
+.Sp
+.Vb 1
+\& Some ("eth0", "192.168.2.5", "255.255.255.0", "192.168.2.1", "192.168.2.1")
+.Ve
.ie n .IP """hypervisor""" 4
.el .IP "\f(CWhypervisor\fR" 4
.IX Item "hypervisor"
reserved for Xen guests. These \s-1MAC\s0 addresses are not tested for
uniqueness so there is a very small chance that they could coincide,
which would leave a guest unable to access the virtual network.
+.ie n .IP """compression""" 4
+.el .IP "\f(CWcompression\fR" 4
+.IX Item "compression"
+Set this to \f(CW\*(C`Some false\*(C'\fR to disable compression, or \f(CW\*(C`Some true\*(C'\fR to
+enable compression, or \f(CW\*(C`None\*(C'\fR to ask the user.
.Sh "\s-1ISO\s0 \s-1ATTACHMENTS\s0"
.IX Subsection "ISO ATTACHMENTS"
Rebuilding a custom \s-1ISO\s0 is time\-consuming. You can make a \*(L"quick\*(R"
where \f(CW\*(C`qemuimage.img\*(C'\fR is the name of the \s-1QEMU/KVM\s0 image.
.PP
You can also supply an \f(CW\*(C`HDB\*(C'\fR parameter to specify a second disk.
+.SH "MAILING LIST"
+.IX Header "MAILING LIST"
+Please direct questions to the et-mgmt-tools mailing list
+<http://www.redhat.com/mailman/listinfo/et\-mgmt\-tools>
+<et\-mgmt\-tools @ redhat . com>
.SH "SEE ALSO"
.IX Header "SEE ALSO"
\&\fIvirsh\fR\|(1),